MACRO-TECH 3600VZ SPECIFICATIONS |
|
POWER |
| Load Impedance: Rated for 16, 8, 4, and 2 ohm use only. Safe with all types of loads, even reactive ones. |
| AC Power Requirements: 100 VAC, 50/60 Hz; 120 VAC, 50/60 Hz; and 230 VAC, 50/60 Hz units are available. 230 VAC, 50/60 Hz units can be used with 220 and 240 VAC. All versions draw 90 watts or less at idle. 100 and 120 VAC units can draw up to 30 amps of current; 230 VAC units can draw up to 15 amps. |
|
PERFORMANCE |
| Frequency Response: ±0.1 dB from 20 Hz to 20 kHz at 1 watt. |
| Phase Response: ±10 degrees from 10 Hz to 20 kHz at 1 watt. |
| Signal-to-Noise Ratio: Greater than 105 dB below rated output (20 Hz to 20 kHz, A-weighted); 100 dB below rated output (20 Hz to 20 kHz, no weighting). |
| Total Harmonic Distortion (THD): At rated output, less than 0.05% from 20 Hz to 1 kHz increasing linearly to less than 0.1% at 20 kHz. |
| Intermodulation Distortion (IMD): Less than 0.05% from 368 milliwatts to full rated output. |
| Damping Factor: Greater than 1,000 from 10 Hz to 400 Hz. |
| Slew Rate: Greater than 30 volts per microsecond. |
| Voltage Gain: (At maximum output) 20:1 ±6% or 26 dB ±0.25 dB at +26 dB sensitivity, and 124.6:1 ±6% or 41.9 dB ±1.0 dB at 0.775 volt sensitivity. |
|
CONTROLS |
| Enable: A front-panel push button used to turn the amplifier on and off. |
| Level: A 31-position detented rotary attenuator for each channel located on the front panel used to control the output level. |
| Stereo/Mono: A three-position back-panel switch used to select Stereo, Bridge-Mono or Parallel-Mono mode. |
| Sensitivity: A three-position switch located inside the PIP compartment used to select one of three input sensitivities for both channels: 0.775 volts or 1.4 volts for standard 1 kHz power or a voltage gain of 26 dB. |
| Input Ground Lift: A two position back panel switch used to isolate the phone jack signal grounds from the chassis (AC) ground. |
| Reset: A back panel button for each channel used to reset the corresponding power supply. 100 and 120 VAC units have 15 amp circuit breakers. 230 VAC units have 7.5 amp circuit breakers. |
|
INDICATORS |
| Enable: This amber indicator is on when the amplifier is switched on to show that the low voltage power supply is operating. |
| Signal/IOC: Two green indicators flash
with medium intensity in sync with the amplifier’s outputs to show signal
presence. In the unlikely event the output waveform differs from that of the input by
0.05% or more, they flash brightly to indicate distortion. As sensitive distortion indicators they provide proof of performance. Note: It is normal for the Channel 2 IOC indicator to remain on in Parallel-Mono mode. |
| ODEP: Each channel has a multifunction LED
(light emitting diode) indicator that shows the channel’s energy reserve status. Normally, the LEDs are brightly lit to show that reserve energy is available. In the rare event that a channel has little reserve, its indicator dims in proportion to ODEP limiting. An ODEP indicator may also turn off under other, more unusual circumstances. |
|
INPUT/OUTPUT |
| Input
Connector: Balanced ¼-inch phone jacks on chassis and internal PIP connector. (Balanced 3-pin XLR connectors are provided on the P.I.P.-FX which is a standard feature.) |
| Input Impedance: Nominally 20 k ohms, balanced. Nominally 10 K ohms, unbalanced. |
| Input Sensitivity: Switchable between 0.775 V (unbalanced) for rated output or a fixed voltage gain of 26 dB. |
| Output Connectors: Color-coded dual binding posts (banana jacks). |
| Output Impedance: Less than 10 milliohms in series with less than 2 microhenries |
| DC Output Offset: (Shorted input) ±10 millivolts. |
|
OUTPUT SIGNAL |
| Stereo: Unbalanced, two-channel |
| Bridge-Mono: Balanced, single-channel. Channel 1 controls are active; Channel 2 controls are inactive and not removed from operation. |
| Parallel-Mono: Unbalanced, single-channel.
Channel 1 controls are active; Channel 2 controls are inactive but not removed from operation. |
|
PROTECTION |
| Macro-Tech amplifiers are protected against
shorted, open or mismatched loads; overloaded power supplies; excessive temperature, chain destruction phenomena, input overload damage and high-frequency blow-ups. They also protect loudspeakers from input/output DC and turn-on/turn-off transients. If unreasonable operating conditions occur, the patented ODEP circuitry proportionally limits the drive level to protect the output devices, particularly in the case of elevated temperature. Transformer overheating results in a temporary shutdown of the offending channel. When it has cooled to a safe temperature, the transformer automatically resets itself. Controlled slew rate voltage amplifiers protect against RF burnouts, and input overload protection is provided by current-limiting resistance at the input. Turn On: The four second turn-on delay prevents dangerous turn-on transients. Turn-on occurs at zero crossing of the AC waveform, so power sequencers are rarely needed with multiple units. Note: The turn-on delay time may be changed. Contact Crown’s Technical Support Group for details. |
| Circuit Breaker: Circuit breaker current ratings vary based on the AC operating power. |
|
CONSTRUCTION |
| Chassis: Steel
chassis with durable black finish, aluminum front panel with Lexan
overlay, and specially designed flow-through ventilation from front to back panels. |
| Cooling: Forced-air with custom heat diffusers
and patented circuitry to promote uniform dissipation. |
| Dimensions: 19 inch (48.3 cm) standard rack
mount (EIA Std. RS-310-B), 3.5 inch (8.9 cm) height, 16 inch (40.6 cm) depth behind mounting surface and 2.5 inches (6.4 cm) in front of mounting surface. |
|
WEIGHT |
| Macro-Tech 3600VZ: 120 VAC, 60 Hz Units: Net weight 55 lbs, 1.5 ounces (25.0 kg); shipping weight 63 lbs, 10 ounces (28.9 kg). |
| Center Of Gravity: Center of gravity is 6 inches (15.2 cm) behind the front mounting surface. |
US Speaker, LLC